LIGNUM – Holzwirtschaft Schweiz | Economie suisse du bois | Economia svizzera del legno
Mühlebachstrasse 8 | 8008 Zürich | Tel. 044 267 47 77 | Fax 044 267 47 87 | info@lignum.ch

> Printversion

Components

Construction assembly A2733

Lignum ID-№
A2733
Catalog number
A.1.03.--
Source of construction assembly
PB 168 30649_X15+X16_DE, Year 2005
Base structure
Ribs / joists
Paneling
Without covering
Reference fire protection
Lignum Dok. 4.1 / Tabelle: 431 (Balken) oder 432 (Rippen) Gilt nicht für Bauteile mit Beschwerung im Hohlraum.
Construction height
314 mm
Weight
374 kg/m2
U-value
≈ 0.303 W/m2K
GWP
38.70 kg CO2-eq/m2
Type sound insulation
Measurement
Ceiling consisting of a basic construction of ribs / joists, single sheathed, without ceiling covering, with dampening in supporting structure, without cavity insulation in the supporting structure. Without dampening on the supporting structure, with impact sound insulation with a dynamic stiffness [s'] of 0.2 MN/m³ and with cement screed.
Values of airborne sound insulation
Rw 78 dB
C -3 dB
C50-3150 -10 dB
Values of footfall sound insulation
Ln,w 37 dB
CI 0 dB
CI50-2500 7 dB

Graphic

Assembly

Layer Product Manufacturer Thickness [mm] Weight Width (b) Axial distance (e) KBOB ID-№ Production KBOB ID-№ Disposal

Values by frequency

Color Type 25 32 40 50 63 80 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000
Airborne sound (R) Measurement Ift Rosenheim 31 37 45 51 55 61 68 73 70 73 75 79 82 84 84 86 88 88 87 88 85
Calculation Lignum/Kühn and Blickle 15 17 20 23 25 28 30 29 32 35 37 40 43 45 46 45 46 55 63 70 79 87
Impact sound (Ln) Measurement Ift Rosenheim 57 47 45 45 45 40 37 38 45 41 39 34 34 32 29 29 25 20 12 9 8
Calculation Lignum/Kühn and Blickle 66 67 67 67 68 68 69 73 73 73 74 74 74 75 77 81 83 77 72 68 62 57

Airborne sound (R)

Loading...

Impact sound (Ln)

Loading...

Ecological indicators according to the KBOB life cycle assessment data in the construction sector KBOB / ecobau / IPB 2009/1:2022, Version 6
(For the life cycle phases production and disposal, excluding the construction phase (Modules A4, A5) and the use phase (Module B), especially replacement (Module B4) or amortization periods according to SIA 2032)

bSDD Properties
mm Indicators Modules
Values / m2
+
Environmental impact points (UBP)
86079
UBP'21/m2
A1-A3 + C1-C4
 
Environmental impact points from production (UBP_pro)
68062
UBP'21/m2
A1-A3
 
Environmental impact points from disposal (UBP_dis)
18018
UBP'21/m2
C1-C4
+
Total primary energy (PE_T)
712.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy from production (PE_pro)
688.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, energetically consumed (PE_E_pro)
331.50
kWh oil-eq/m2
A1-A3
 
Primary energy production, materially bound (PE_M_pro)
358.70
kWh oil-eq/m2
A1-A3
 
Primary energy from disposal (PE_dis)
23.80
kWh oil-eq/m2
C1-C4
+
Renewable primary energy (PE_RT)
569.40
kWh oil-eq/m2
A1-A3 + C1-C4
 
Renewable primary energy from production (PE_RT_pro)
568.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from generation, energetically consumed (PE_RE_pro)
217.10
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from production, materially bound (PE_RM_pro)
350.20
kWh oil-eq/m2
A1-A3
 
Renewable primary energy from disposal (PE_RT_dis)
1.20
kWh oil-eq/m2
C1-C4
+
Total use of non- renewable primary energy resources (PE_NRT)
144.50
kWh oil-eq/m2
A1-A3 + C1-C4
 
Primary energy not renewable from manufacturing (PE_NRT_pro)
121.90
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, energetically consumed (PE_NRE_pro)
113.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from production, materially bound (PE_NRM_pro)
8.40
kWh oil-eq/m2
A1-A3
 
Primary energy not renewable from disposal (PE_NRT_dis)
22.70
kWh oil-eq/m2
C1-C4
+
Total greenhouse gas emissions (GWP_total)
38.70
kg CO2/m2
A1-A3 + C1-C4
 
Greenhouse gas emissions from manufacturing (GWP_pro)
31.50
kg CO2/m2
A1-A3
 
Greenhouse gas emissions from waste disposal (GWP_dis)
7.20
kg CO2/m2
C1-C4
 
Biogenic carbon dioxide storage (bio-C x 44/12 = bio-CO2) (Not included in GWP)
112.20
kg CO2/m2
B1-B7
 
Biogenic carbon storage (bio-C) (Not included in GWP)
30.60
kg C/m2
B1-B7
⇒ Advantages of the life cycle assessment outside the system boundary (module D)